Description
The probe of this product adopts a right angle design, and the length of the temperature measuring end can be adjusted according to the hole depth. The terminal and lead protection adopt explosion-proof design, which is safe and reliable. Used for bearing temperature measurement of explosion-proof motors and generators.
Technical parameters
Temperature measuring end material | Leads | ||||
Length | Specification | Insulation material | Operation temperature | Shield | |
Metal | Standard lead length 1000mm User defined non-standard lead length | 2×0.2mm2 3×0.2mm2 4×0.2mm2 | Teflon | -50℃~200℃ | With or without shielding |
Product features
1. The temperature sensor probe housing of this model can be customized with different lengths and sizes according to the usage environment requirements.
2. The temperature sensor lead material of this model is Teflon, and different models such as shielded and unshielded can be customized according to the usage environment requirements.
3. This model of temperature sensor can be customized with explosion-proof and high-pressure temperature sensors
Adjustable
Model Example:WZP-MB3-206(Prototype number WZPM-206B3)
WZP | W temperature instrument Z thermal resistance P platinum thermal resistance (P2 is a dual chip) |
M | Bearing temperature measurement |
B | B metal protective sleeve C plastic protective sleeve D composite protective sleeve |
3 | Right angle adjustable |
206 | 2 with fixed device 06 temperature measuring end Φ 6 |
Ordering Example:WZP-MB3-206/45-M12×1-900- M14×1.25-P3×1000
55 | Installation hole depth |
M12×1 | Temperature measurement end thread specification |
900 | Length of protective sleeve |
M14×1.25 | Terminal thread specifications |
P | Shielding wire |
3×1000 | Three wire system × Line length |
Fixed type
Model Example:WZP-MB4-206 (Prototype number WZPM-206B4)
WZP | W temperature instrument Z thermal resistance P platinum thermal resistance (P2 is a dual chip) |
M | Bearing temperature measurement |
B | B metal protective sleeve C plastic protective sleeve D composite protective sleeve |
4 | Right angle fixed type |
206 | 2 with fixed device 06 temperature measuring end Φ 6 |
Model Example:WZP-MB2-206/55-M12×1-900- M14×1.25-P3×1000
55 | Installation hole depth |
M12×1 | Temperature measurement end thread specification |
900 | Length of protective sleeve |
M14×1.25 | Terminal thread specifications |
P | Shielding wire |
3×1000 | Three wire system × Line length |
Note
Attention 3.1 During installation, protect the sensor lead out cable and do not pull it forcefully;
3.2After the installation and connection of the sensor are completed, it is necessary to verify whether the wiring is correct and confirm before proceeding.It can avoid damage caused by strong electricity mistakenly connecting to sensors;
3.3 When the storage period of the sensor exceeds 1 year, the temperature resistance value and insulation resistance value of the sensor should be tested before installation to determine its good performance.
Description
The probe of this product adopts a right angle design, and the length of the temperature measuring end can be adjusted according to the hole depth. The terminal and lead protection adopt explosion-proof design, which is safe and reliable. Used for bearing temperature measurement of explosion-proof motors and generators.
Technical parameters
Temperature measuring end material | Leads | ||||
Length | Specification | Insulation material | Operation temperature | Shield | |
Metal | Standard lead length 1000mm User defined non-standard lead length | 2×0.2mm2 3×0.2mm2 4×0.2mm2 | Teflon | -50℃~200℃ | With or without shielding |
Product features
1. The temperature sensor probe housing of this model can be customized with different lengths and sizes according to the usage environment requirements.
2. The temperature sensor lead material of this model is Teflon, and different models such as shielded and unshielded can be customized according to the usage environment requirements.
3. This model of temperature sensor can be customized with explosion-proof and high-pressure temperature sensors
Adjustable
Model Example:WZP-MB3-206(Prototype number WZPM-206B3)
WZP | W temperature instrument Z thermal resistance P platinum thermal resistance (P2 is a dual chip) |
M | Bearing temperature measurement |
B | B metal protective sleeve C plastic protective sleeve D composite protective sleeve |
3 | Right angle adjustable |
206 | 2 with fixed device 06 temperature measuring end Φ 6 |
Ordering Example:WZP-MB3-206/45-M12×1-900- M14×1.25-P3×1000
55 | Installation hole depth |
M12×1 | Temperature measurement end thread specification |
900 | Length of protective sleeve |
M14×1.25 | Terminal thread specifications |
P | Shielding wire |
3×1000 | Three wire system × Line length |
Fixed type
Model Example:WZP-MB4-206 (Prototype number WZPM-206B4)
WZP | W temperature instrument Z thermal resistance P platinum thermal resistance (P2 is a dual chip) |
M | Bearing temperature measurement |
B | B metal protective sleeve C plastic protective sleeve D composite protective sleeve |
4 | Right angle fixed type |
206 | 2 with fixed device 06 temperature measuring end Φ 6 |
Model Example:WZP-MB2-206/55-M12×1-900- M14×1.25-P3×1000
55 | Installation hole depth |
M12×1 | Temperature measurement end thread specification |
900 | Length of protective sleeve |
M14×1.25 | Terminal thread specifications |
P | Shielding wire |
3×1000 | Three wire system × Line length |
Note
Attention 3.1 During installation, protect the sensor lead out cable and do not pull it forcefully;
3.2After the installation and connection of the sensor are completed, it is necessary to verify whether the wiring is correct and confirm before proceeding.It can avoid damage caused by strong electricity mistakenly connecting to sensors;
3.3 When the storage period of the sensor exceeds 1 year, the temperature resistance value and insulation resistance value of the sensor should be tested before installation to determine its good performance.